  1. What does "1 Gang", "2 Gang", and so forth mean when talking …

    It refers to the width of the box. A 1-gang box is wide enough for a switch or duplex receptacle. The idea is that you can "gang" up electrical components in the box.

  2. Ok to install NEMA 14-50R in plastic, new-work, single-gang box?

    It's OK to use that device with a single gang cover plate, but that doesn't mean a single gang device box is allowable. You would use a single gang device ring on a 4x4 (or larger) box with …

  3. Standard electrical wall mounting box specifications for the USA

    Jul 12, 2017 · I was wondering what the standard electrical wall mounting box used for sockets in america was. I was also wondering what the specifications for these boxes were, as well as, …

  4. electrical - 1 gang box fill capacity/size for receptacal and two 12/2 ...

    Jul 2, 2023 · The box will have two 12/2 romex, one line, one load, plus 3 pigtails to the device (ground, common & hot). Pretty much the standard setup that I've seen in most receptacle boxes.

  5. drywall - How can I secure this metal 1-gang electrical box without ...

    Dec 27, 2018 · So for this application, a box without holdfast clamps is preferred.) As mentioned above, code requires that the opening fit tight to the box, and it's hard to make a hole smaller. …

  6. Is it safe to do a three-way splice in a single gang junction box?

    Aug 20, 2020 · The combination switch would be single gang as well since it is going into a narrow space (an area of wall between a door frame and a chimney). I have done some …

  7. Can I mount a ceiling light fixture on a wall to a 1-gang …

    Dec 28, 2021 · I want to replace a wall mounted light fixture. When I took it off the wall I realized the box behind it was a rectangular 1-gang: The previous circular light was mounted to the wall …

  8. electrical - Can cables entering a box have their sheath removed …

    Mar 6, 2024 · The box connects to the outlet above and to the right, which a washing machine is plugged into. Does the exposed copper wire present a fire or shock hazard? If so, can I fix this …

  9. Can I change a 1-gang electrical box to a 2-gang electrical box?

    I live in a house built in the 50's in Maryland, US. Each bedroom contains 4 electrical outlets - configured in two 1-gang electrical boxes on opposing walls. However, with all the modern …

  10. How to extend an outdoor single gang electrical box to a 2 gang ...

    Jun 15, 2022 · I have a single gang electrical box on an outside wall of my home. I need to expand it so it can house two GFCI outlets on separate circuits. I have been looking for an …